Broken Neutral Safety Device SYSTEM


Patent Pending

The unit is designed to detect a broken neutral condition from the supply authority incoming supply. Once a broken neutral condition is detected it creates a situation for the Residual Current Device (RCD or Earth Leakage unit) to operate and isolate the single-phase load from the incoming supply.

Brochure Request


Please enter your name & surname
Please enter a valid email address
Please enter your company name
Please enter a valid contact number
Invalid Input

Operation

The unit is designed to detect a broken neutral condition from the supply authority incoming supply.

Once a broken neutral condition is detected it creates a situation for the Residual Current Device (RCD or Earth Leakage unit) to operate and isolate the single-phase load from the incoming supply.

Without this device, a broken neutral condition will not be detected and create an unsafe safe environment with a high risk of electrocution in this condition. The device will also ensure that appliances connected to the single-phase load are protected under broken neutral overvoltage conditions.

Specification

  • Current limitation to 30mA at 230V with RCD
  • Does not operate for load unbalanced voltages
  • Overvoltage Protection (250V MOV)
  • Blue 1.5mm² - Source Neutral wire (300mm)
  • Black 1.5mm² - Load Neutral wire (300mm)
  • Green/Yellow 1.5mm² - Earth wire (300mm)
  • Fire retardant resin coating
  • Unit Dimension: 70mm(L) x 50mm(H) x 25mm

Installation

  • Installations must be done by an authorized person certified to work on electrical low voltage (230V) network installations.
  • Before installation commences the RCD (Earth Leakage unit) must be tested by pushing the trip test button. Failure for the RCD to operate under test conditions must stop the process of installation until the RCD has been replaced and tested for correct functionality.
  • Step 1 – Test the RCD for correct operation.
  • Step 2 – Measure incoming supply between Phase and Earth and Neutral and Earth.
    • Phase-Earth should be 230V
    • Neutral-earth should be very close to 0V (If greater than 10% of supply notify authority i.e. 23V)
  • Step 3 – Isolate the incoming supply by tripping the RCD.
  • Step 4 – Measure the load side to confirm that the supply is dead and that the RCD is working correctly.
  • Step 5 – Install the BNSD in the distribution box as follows:
    • BLUE wire to incoming SOURCE NEUTRAL on RCD
    • BLACK wire to outgoing LOAD NEUTRAL on RCD
    • GREEN/YELLOW wire to EARTH BAR in distribution box.
  • Step 6 – Once installed reset the RCD and measure supply voltages to be healthy.
  • Step 7 – The RCD should be stable and should not trip under normal conditions.
  • NOTE: LOAD MUST BE CONNECTED FOR DEVICE TO OPERATE CORRECTLY
  • IMPORTANT: ENSURE EARTHING IN DISTRIBUTION BOX COMPLIES TO SPECIFICATIONS
BROKEN-NEUTRAL-SAFETY-DEVICE-system

Follow our Social Media Pages


Facebook

Twitter

LinkedIn

Youtube

Our Clients


    Get in touch


    Contact us on +27 86 069 0712 if you need assistance or want to speak to a friendly consultant.

      • Telephone:
        +27 86 069 0712
      • Email:
        This email address is being protected from spambots. You need JavaScript enabled to view it.
        This email address is being protected from spambots. You need JavaScript enabled to view it.
      • Location:
        23 Chasewater Street New Redruth Alberton 1449

      • Invalid Input
        Invalid Input
        Invalid Input
        Invalid Input
        Invalid Input

    026977

    Your IP: 54.226.175.101
    2019-03-20 01:05

    Job Application


    EMPLOYMENT APPLICATIONS

    / Invalid Input
    Invalid Input
    PERSONAL INFORMATION

    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    EDUCATION HISTORY

    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    CURRENT/LAST AND PREVIOUS EMPLOYMENT

    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    EMPLOYMENT HISTORY

    Employment reference 1

    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Employment reference 2

    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Employment reference 3

    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Employment reference 4

    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Employment reference 5

    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Employment reference 6

    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Employment reference 7

    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Employment reference 8

    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Employment reference 9

    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Employment reference 10

    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input

    Job Application


    EMPLOYMENT APPLICATIONS

    / Invalid Input
    Invalid Input
    PERSONAL INFORMATION

    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    EDUCATION HISTORY

    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    CURRENT/LAST AND PREVIOUS EMPLOYMENT

    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    EMPLOYMENT HISTORY

    Employment reference 1

    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Employment reference 2

    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Employment reference 3

    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Employment reference 4

    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Employment reference 5

    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Employment reference 6

    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Employment reference 7

    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Employment reference 8

    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Employment reference 9

    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Employment reference 10

    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input
    Invalid Input